Clean Marine Systems came onboard to help diagnose a generator fault and also to confirm sea water flow rates to our shaft bearings using the portable ultrasonic flow meter.
By comparing the information displayed we were able to determine one of our generators was not getting enough salt water flow which was causing it to run hotter than usual. We then knew where to focus our attention and located where air was getting into the suction side of the raw water pump.
We were also able to determine the exact flow rate and volume of salt water cooling to our shaft bearings after a refit, we then compared the results to the manufacturer’s specifications confirming that recommended standards had been met. It also gives us a datum for us to work with in the future if we incur any unforeseen problems.
I found the Aqua Sonar system to be a very effective and efficient fault finding tool, I also believe it would be a great advantage to have onboard as a fitted system to detect possible faults and defects early on.
I dealt with Perry Anderson personally who I found to be very knowledgeable and professional.

Jeremy Hurst
Engineer
M/Y Four Wishes